Horiba 1000 mg/L Ammonium Ion Standard Solution, 500ml (500-NH4-SH)

Product number: 895916

Product information "Horiba 1000 mg/L Ammonium Ion Standard Solution, 500ml (500-NH4-SH) "

HORIBA Ion standard solutions, ionic strength controllers and ion-selective electrode filling solutions are indispensable for accurate and reproducible measurements with ion-selective electrodes (ISE). A large number of analyses in laboratories and in the field, such as testing water and wastewater quality, environmental monitoring and quality control in industrial processes, rely on these solutions.

Ionic standard solutions are used to calibrate ion-selective electrodes and ensure precise measurement. Horiba's standard solutions have a known ion concentration. They are therefore essential for setting up the electrodes correctly before using them for test runs.

Ionic strength regulators are specifically designed to adjust the ionic strength of the sample to enable accurate measurements. They are particularly important when the composition of the samples could affect the measurement or in samples with low ionic strength. The ionic strength can be adjusted to stabilize the ionic activity in the solution. This leads to more accurate measurement results.

Ion-selective electrode filling solutions
Ion-selective electrode filling solutions are specific solutions that are filled into ion-selective electrodes. They ensure the proper operation of the electrode and help to maintain the potential required to measure the specific ion.

To ensure that measurements meet international standards and to ensure conformity with regulatory and compliance standards, these specialized solutions are essential. Many industries, from pharmaceutical to environmental, use these solutions to meet their quality and safety requirements.

For users working in areas such as water analysis, environmental monitoring or regulatory testing environments, these solutions ensure the accuracy and reliability required for critical measurements. To provide reliable data for important environmental, health and safety decisions, they are a crucial part of analytical chemistry. Overall, HORIBA's solutions enable experts to make the best use of their instruments and achieve the precise results required for their applications.

Dimensions

Height 13,6 cm
Length 8,5 cm
Width 6,5 cm

Weight

Weight 570 g

Other attributes

Brand Horiba
Skip product gallery

Wir empfehlen Ihnen dazu:

Tip
Horiba 300-NH4-C
Product number: 896062
Ammonium (NH4+) ion-selective electrode for 300 seriesThe new electrode is suitable for the LAQUA WQ-300 series from Horiba and offers precise and reliable measurements for ions in aqueous solutions. It is characterized by its user-friendly handling and environmentally friendly design and is versatile in useFeatures:Measurement parameters: Ammonium solid-state electrodes that do not require refillingDouble junction made of porous sintered polyethyleneIntegrated temperature sensorEnvironmentally friendly design made from bio-based plasticSupplied with calibration and ionic strength adjustment solutionsRobust housing made of polycarbonate and PVCLow maintenance, simply rinse and seal Waterproof according to IP67Linearity in the measuring range:The range in which the calibration curve shows linearity is called the measuring range. If a lower concentration is measured at which the linearity is not given, the calibration must be carried out at two points in the lower concentration range.Influence of the pH value:The ammonia electrode can be used in a pH range from 5 to 8. The influence of the pH value can cause a decrease in the slope of the ion-selective electrode or a parallel shift of the calibration curve. To avoid these effects, set the pH value to a suitable value in advance and keep it constant. Interfering ions:Ion-selective electrodes have good selectivity with respect to the ions being measured, but can react to other ions. When using the ion electrode method, it is important to be aware of the effects of coexisting ions and to take measures to avoid them. Interfering ions can form compounds with poor solubility or form complex salts with the structural material of the ion-selective membrane, which can significantly affect the measured value.Conditioning:An electrode is conditioned by immersing it in a standard solution for 1 hour or longer. Use a standard solution with a concentration of 100 mg/L or more. In the following cases, the electrode must be conditioned before calibration. Before first use. Before use after storage for 2 weeks or longer. When the electrode is less sensitive.Calibration:Always calibrate with at least 2 calibration solutions that are a decade apart and include the expected reading. Use fresh calibration solutions and do not reuse them.- Below 10 ppm (mg/L)First solution between 1 and 10 ppmSecond solution between 10 and 50 ppm- Between 10 and 100 ppm (mg/L)First solution between 10 and 100 ppmSecond solution between 100 and 1000 ppm- Over 100 ppm (mg/L)First solution between 100 and 1000 ppmSecond solution above 1000 ppmFurther information can be found in the download area of the store.