Skip to main content

Horiba LAQUAtwin ORP Tester with 1 calibration point and temperature measurement (ORP-11)

Product number: 895692

Product information "Horiba LAQUAtwin ORP Tester with 1 calibration point and temperature measurement (ORP-11)"

Manufacturer Part No. 3200965260

LAQUAtwin ORP-11: The world's first pocket-sized ORP and Eh meter

Your mobile laboratory - for use on site: Ideal for water quality tests in swimming pools, environmental tests and many other applications.

HORIBA's unique compact meter integrates electrode, display and sample container to enable simple, effective on-site testing by direct measurement with a single drop. 

Versatile measurement: The only pocket-sized ORP meter that can measure not only the ORP value but also the Eh value (voltage measurement versus the standard hydrogen electrode or SHE)

Precision in every drop: The replaceable sensor with platinum disc enables measurements in samples as small as 0.3 ml (or 0.05 ml with sampling sheet).

Wide measuring range: With a measuring range from -1000 mV to 1000 mV, the meter ensures accurate readings over a wide range.

Simple automatic one-point calibration: The meter automatically recognises and calibrates the 225 mV standard solution included in the kit. The calibration can be adjusted with a different ORP standard solution.

Exceptional accuracy: With an accuracy of +/- 2 mV, the meter delivers precise results every time.

Auto Stable & Auto Hold measurement modes: To help users record stable readings, the meter displays a smiley face and can freeze the reading.

Temperature Compensation and Calibration: The meter displays temperatures up to 50.0 °C and allows for temperature compensation and correction through its calibration function.

IP67 rating: Water and dustproof meter with digital LCD display and backlighting

Complete package for ORP testing on the go: Each ORP-11 meter comes with a 225 mV ORP standard solution (14 ml), a cotton swab for polishing the platinum disc, a pipette, batteries and 5 sampling sheets.

Dimensions

Height 3,4 cm
Length 18,2 cm
Width 14,3 cm

Weight

Weight 300 g

Other attributes

Brand Horiba
Country of origin JP
Customs tariff number 9027890001
Parameter ORP
Quality Advanced
Technical data
Measuring principle:  ORP electrode 
Minimum sample volume: 0.3 ml (0.05 ml with sampling sheet B)
ORP measuring range / resolution: -1000 to 1000 mV / 1 mV
Accuracy: ± 2 mV
Maixed calibration points:  1
Temperature display / resolution: 0 to 50.0 °C / 0.01 °C

 

Functions

- ORP and Eh measurements
- Automatic standard detection 
- Automatic / user-defined calibration values 
- Temperature compensation 
- Temperature calibration 
- Auto-hold / auto-stable measurement modes
- Automatic switch-off (30 min.) 
- Low battery indicator 
- IP67 water and dust proof
- Replaceable sensor 
Display:  Custom (monochrome) digital LCD with backlight 
Operating temperature / humidity:  5 to 40.0 °C / 85% or less relative humidity (no condensation)
Battery life:  approx. 400 hours of continuous operation without backlight 
Material: ABS epoxy housing / platinum disk sensor 
Dimensions: 164 x 29 x 20 mm (without protrusions)
Weight: approx. 55g (including sensor and battery)

 

Included accessories

- 225 mV ORP standard (14 ml)
- Lint-free cotton swab 
- CR2032 batteries (2 pcs.)
- Pipette
- Instructions for use & short manual 
- Storage case

Replacement sensor, calibration standards and accessories

Horiba LAQUAtwin S080-ORP Redox Replacement Sensor for ORP-11 tester
Product number: 895694
Measurement parameters: ORP | Temperature
Manufacturer Part Nr. 3200997083

€75.00*
Horiba Redox 255 mV Buffer Solution (514-ORP-225)
Product number: 895696
Measurement parameters: ORP
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200997084

€58.00*
HORIBA ORP 200mV (±5mV @25°C) buffer solution 250ml (250-ORP-200)
Product number: 895972
ORP Buffer: 200 mV (±5mV @25°C) | Size of bottle: 250 ml |
Explore HORIBA's premium profile solutions for pH, ORP and conductivity measurements, specifically designed for handheld and laboratory meters. Our solutions are designed to meet the needs of different users and ensure that your measurements are accurate. Here are a few of our products that provide a clear overview and easy selection: - pH standard solutions are available in different pH value classes: e.g. 4.01, 7.00, 10.01. These solutions are indispensable for the calibration of pH electrodes and have a high degree of accuracy. - Redox standard solutions (ORP): These solutions offer values from 200 mV to 650 mV, enabling precise adjustment of redox electrodes. Standard solutions for conductivity: These are used to calibrate conductivity sensors and are available in different conductivity ranges. - Internal filling solutions: These solutions are specially designed for pH and reference electrodes and ensure optimum functionality as well as a long service life for your electrodes. Users:- Our NIST-traceable hygienic bottle solutions are ideal for environmental laboratories using pH and ORP buffer solutions to monitor water quality in natural waters. They enable safe and accurate calibration without the risk of contamination. - Our buffer solutions provide a reliable basis for compliant results in the pharmaceutical industry, where accurate pH measurements are critical for drug formulation and quality control. - Our pH and redox solutions are of great importance to the food and beverage industry and play a crucial role in the quality of products, from wine production to milk processing. - Our solutions are used by research institutions and universities to conduct their scientific experiments and train the next generation of scientists. - Our conductivity standard solutions are used by water treatment plants to improve their purification and filtration processes. Manufacturer information: Because HORIBA is synonymous with quality and precision, you can trust our professional solutions to complement your measurement equipment and extend its life. HORIBA's innovative hygienic bottles differ significantly from conventional bottles as they allow contamination-free removal by simply squeezing. As the lower part of the bottle always remains fresh and untouched, it is particularly advantageous for applications where cleanliness and accuracy are crucial. Use HORIBA solutions to ensure the accuracy of your measurements and promote the functionality of your measuring devices. HORIBA High quality ORP buffer solution for calibration of your ORP electrodes The 250 ml and 500 ml bottle is characterized by a special hygienic closure, which protects the ORP buffer solution from contamination. To provide the required buffer, simply squeeze the bottle together and enough buffer solution is delivered to the upper part of the bottle to perform a calibration.

€36.00*
HORIBA ORP 475mV (±5mV @25°C) buffer solution 250ml (250-ORP-475)
Product number: 895973
ORP Buffer: 475 mV (±5mV @25°C) | Size of bottle: 250 ml |
Explore HORIBA's premium profile solutions for pH, ORP and conductivity measurements, specifically designed for handheld and laboratory meters. Our solutions are designed to meet the needs of different users and ensure that your measurements are accurate. Here are a few of our products that provide a clear overview and easy selection: - pH standard solutions are available in different pH value classes: e.g. 4.01, 7.00, 10.01. These solutions are indispensable for the calibration of pH electrodes and have a high degree of accuracy. - Redox standard solutions (ORP): These solutions offer values from 200 mV to 650 mV, enabling precise adjustment of redox electrodes. Standard solutions for conductivity: These are used to calibrate conductivity sensors and are available in different conductivity ranges. - Internal filling solutions: These solutions are specially designed for pH and reference electrodes and ensure optimum functionality as well as a long service life for your electrodes. Users:- Our NIST-traceable hygienic bottle solutions are ideal for environmental laboratories using pH and ORP buffer solutions to monitor water quality in natural waters. They enable safe and accurate calibration without the risk of contamination. - Our buffer solutions provide a reliable basis for compliant results in the pharmaceutical industry, where accurate pH measurements are critical for drug formulation and quality control. - Our pH and redox solutions are of great importance to the food and beverage industry and play a crucial role in the quality of products, from wine production to milk processing. - Our solutions are used by research institutions and universities to conduct their scientific experiments and train the next generation of scientists. - Our conductivity standard solutions are used by water treatment plants to improve their purification and filtration processes. Manufacturer information: Because HORIBA is synonymous with quality and precision, you can trust our professional solutions to complement your measurement equipment and extend its life. HORIBA's innovative hygienic bottles differ significantly from conventional bottles as they allow contamination-free removal by simply squeezing. As the lower part of the bottle always remains fresh and untouched, it is particularly advantageous for applications where cleanliness and accuracy are crucial. Use HORIBA solutions to ensure the accuracy of your measurements and promote the functionality of your measuring devices. HORIBA High quality ORP buffer solution for calibration of your ORP electrodes The 250 ml and 500 ml bottle is characterized by a special hygienic closure, which protects the ORP buffer solution from contamination. To provide the required buffer, simply squeeze the bottle together and enough buffer solution is delivered to the upper part of the bottle to perform a calibration.

€36.00*
HORIBA ORP 650mV (±5mV @25°C) buffer solution 500ml (500-ORP-650)
Product number: 895975
ORP Buffer: 650 mV (±5mV @25°C) | Size of bottle: 500 ml |
Explore HORIBA's premium profile solutions for pH, ORP and conductivity measurements, specifically designed for handheld and laboratory meters. Our solutions are designed to meet the needs of different users and ensure that your measurements are accurate. Here are a few of our products that provide a clear overview and easy selection: - pH standard solutions are available in different pH value classes: e.g. 4.01, 7.00, 10.01. These solutions are indispensable for the calibration of pH electrodes and have a high degree of accuracy. - Redox standard solutions (ORP): These solutions offer values from 200 mV to 650 mV, enabling precise adjustment of redox electrodes. Standard solutions for conductivity: These are used to calibrate conductivity sensors and are available in different conductivity ranges. - Internal filling solutions: These solutions are specially designed for pH and reference electrodes and ensure optimum functionality as well as a long service life for your electrodes. Users:- Our NIST-traceable hygienic bottle solutions are ideal for environmental laboratories using pH and ORP buffer solutions to monitor water quality in natural waters. They enable safe and accurate calibration without the risk of contamination. - Our buffer solutions provide a reliable basis for compliant results in the pharmaceutical industry, where accurate pH measurements are critical for drug formulation and quality control. - Our pH and redox solutions are of great importance to the food and beverage industry and play a crucial role in the quality of products, from wine production to milk processing. - Our solutions are used by research institutions and universities to conduct their scientific experiments and train the next generation of scientists. - Our conductivity standard solutions are used by water treatment plants to improve their purification and filtration processes. Manufacturer information: Because HORIBA is synonymous with quality and precision, you can trust our professional solutions to complement your measurement equipment and extend its life. HORIBA's innovative hygienic bottles differ significantly from conventional bottles as they allow contamination-free removal by simply squeezing. As the lower part of the bottle always remains fresh and untouched, it is particularly advantageous for applications where cleanliness and accuracy are crucial. Use HORIBA solutions to ensure the accuracy of your measurements and promote the functionality of your measuring devices. HORIBA High quality ORP buffer solution for calibration of your ORP electrodes The 250 ml and 500 ml bottle is characterized by a special hygienic closure, which protects the ORP buffer solution from contamination. To provide the required buffer, simply squeeze the bottle together and enough buffer solution is delivered to the upper part of the bottle to perform a calibration.

€50.00*