Skip to main content Skip to search Skip to main navigation

Horiba LAQUAtwin Salinity Tester with 2 calibration points and temperature measurement (Salt-22)

Product number: 896060

Product information "Horiba LAQUAtwin Salinity Tester with 2 calibration points and temperature measurement (Salt-22)"

Manufacturer Part No. 3200689158

LAQUAtwin SALT-22: The world's first pocket-sized salinity analyser.

Your mobile laboratory - for use on site: Ideal for water quality testing in aquariums, food and many other applications.

HORIBA's unique compact meter integrates electrode, display and sample container to enable simple, effective on-site testing by direct measurement with a single drop.

  • Minimum sample volume: 0.3 ml (0.05 ml with sampling sheet B)
  • Displays salinity, mV and temperature
  • Up to 2 calibration points
  • Automatic calibration
  • Automatic standard detection: 0.5 & 5.0% NaCl (standard)
  • Adjustable high and low calibration values
  • Temperature calibration: 5 to 40.0 ºC
  • Automatically stable / automatically held measurement
  • Automatic switch-off: 30 min.
  • Low battery indicator
  • IP67 rating dust and waterproof
  • Replaceable sensor
  • 400 hours battery life: continuous operation without backlight
  • Material: ABS epoxy
  • Display: customised (monochrome) digital LCD with backlight
  • Operating conditions: 5 to 40 ºC, 85% or less relative humidity
  • Warranty: 2 years - meter; 6 months - sensor
  • Packed in a practical carrying case

Supplied with 0.5 % and 5.0 % NaCl standards (14 ml each), 5 x sampling sheet B, 2 x CR2032 batteries, pipette, instructions and short manual

Dimensions

Height 3,4 cm
Length 19 cm
Width 10 cm

Weight

Weight 190 g

Other attributes

Applications Aquaculture and Coral, Beverages, Environmental, Food, Horticulture, Hydroponics, Laboratory, Pools, Schools, Water Conditioning, Water Treatment, Wine
Brand Horiba
Country of origin JP
Customs tariff number 90278990
Parameter Combined Multiparameter, Salinity
Quality Advanced
Technical data

Measurement Principle: Ion selective electrode

Minimum Sample Volume: 0.3 ml (0.05 with sampling sheet B)
 
Salinity Measurement Range:
0.01 to 25% by weight
 
Resolution:
0.00 to 0.99%: 0.01%
1.0 to 9.9%: 0.1%
10 to 25%: 1%
 
Accuracy: 
± 10% of reading value
Maximum Calibration Points: 2
Temperature Display: 0 to 50.0 ºC 
Temperature Calibration: 5 to 40.0 °C
 
Functions
  • Automatic Standard Recognition
  • Auto calibration
  • Changeable High & Low Calibration Values
  • Temperature Calibration
  • Auto Hold / Auto Stable
  • Automatic Power Off (30 mins.)
  • Low Battery Indicator
  • IP67 Water / Dust Proof
  • Replaceable Sensor
Display: Custom (Monochrome) Digital LCD with Backlight
Operating Temperature / Humidity:
5 to 40 ºC, 85% or less in relative humidity (no condensation)
Battery Life: Approx. 400 hrs. continuous use without backlight
Material: ABS epoxy body 
Dimensions: 164 x 29 x 20 mm(excluding projections)
Mass: Approx. 55g (including sensor and batteries)
 
Accessories included
  • 0.5% & 5.0% NaCl Standard Solutions (14 ml each)
  • Conditioning Solution (4 ml)
  • CR2032 Batteries (2)
  • Dropper
  • Instruction & Quick Manuals

Replacement sensor, calibration standards and accessories

Horiba LAQUAtwin S021 Salt Replacement Sensor for Salt-22 tester
Product number: 896061
Measurement parameters: Salt | Temperature
Manufacturer Part Nr. 3200459866

€200.00*
Horiba 0.5% NaCl Standard Solution (514-05)
Product number: 895672
Measurement parameters: Salinity
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3999960112

€46.00*
Horiba 5.0% NaCl Standard Solution (514-50)
Product number: 895673
Measurement parameters: Salinity
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3999960113

€46.00*
Horiba Conditioning Solution for Conductivity and Salt Sensors (514-20)
Product number: 895674
Measurement parameters: Conductivity & Salt Sensors
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3999960114

€46.00*