Measuring range:
Conductivity: 1 µS/cm to 100 mS/cm | Temperature: 0 to 100 °C
|
Measurement parameters:
Conductivity | Temperature
Manufacturer's number: 3014081545For general useGlass housing, platinum/platinum black, k=1, conductivity cell with integrated temperature sensorWaterproof
Measuring range:
Conductivity: 10µS/cm to 1S/cm | Temperature: 0 to 60 °C
|
Measurement parameters:
Conductivity | Temperature
Manufacturer's number: 3014081714For water with high conductivity
Glass body, platinum/platinum black, k=10, conductivity measuring cell with integrated temperature sensor Waterproof
Measuring range:
Conductivity: 0.1 µS/cm to 10 mS/cm | Temperature: 0 to 60 °C
|
Measurement parameters:
Conductivity | Temperature
Manufacturer's number: 3014082350For water with low conductivity (e.g. pure water)Glass body, platinum/platinum black, k=0.1, conductivity measuring cell with integrated temperature sensor
Measuring range:
Conductivity: 10µS/cm to 100 mS/cm | Temperature: 0 to 60 °C
|
Measurement parameters:
Conductivity | Temperature
Manufacturer number: 3014082592For column chromatography with a very small sample quantityGlass body, platinum/platinum black, k=10, conductivity measuring cell
Measuring range:
pH: 0 to 14 | Temperature: 0 to 60°C
|
Measurement parameters:
pH | Temperature
Manufacturer number: 3014081107This refillable pH electrode can measure samples in very slender test tubes (e.g., NMR test tubes) due to its long, thin, glass-body.Waterproof
Measuring range:
pH: 0 to 14 | Temperature: 0 to 60°C
|
Measurement parameters:
pH | Temperature
Manufacturer number: 3014079136This glass-body, refillable pH electrode with temperature sensor has a sleeve junction for improved stability and repeatability. Ideal for highly accurate pH measurement.
Manufacturer's number: 3200697407
Ion-selective electrodes respond to the concentration of specific ions in the test fluid and are variable potential electrodes. They are used in combination with reference electrodes to measure the concentration of certain ions.
When measuring with an ion meter, the ion concentration can be read directly by calibrating with different standard solutions. Since the volume reading changes with temperature, measurements must be taken at a fixed temperature.
Note:
Chloride sensor, if selected, is supplied without chloride ion strength regulator and chloride electrode filling solution. This must be procured by the customer. Without the filling solution the sensor can´t be used.
Manufacturer's number: 3200693774
Ion-selective electrodes respond to the concentration of specific ions in the test fluid and are variable potential electrodes. They are used in combination with reference electrodes to measure the concentration of certain ions.
When measuring with an ion meter, the ion concentration can be read directly by calibrating with different standard solutions. Since the volume reading changes with temperature, the measurements must be taken at a fixed temperature.
Manufacturer's number: 3200697408
Ion-selective electrodes respond to the concentration of specific ions in the test fluid and are variable potential electrodes. They are used in combination with reference electrodes to measure the concentration of certain ions.
When measuring with an ion meter, the ion concentration can be read directly by calibrating with different standard solutions. Since the volume reading changes with temperature, the measurements must be taken at a fixed temperature.
Manufacturer's Number: 3200697409
Ion-selective electrodes respond to the concentration of specific ions in the test fluid and are variable potential electrodes. They are used in combination with reference electrodes to measure the concentration of certain ions.
When measuring with an ion meter, the ion concentration can be read directly by calibrating with different standard solutions. Since the volume reading changes with temperature, measurements must be taken at a fixed temperature.
Manufacturer's number: 3200697410
Ion-selective electrodes respond to the concentration of specific ions in the test fluid and are variable potential electrodes. They are used in conjunction with reference electrodes to measure the concentration of certain ions.
When measuring with an ion meter, the ion concentration can be read directly by calibrating with different standard solutions. Since the volume reading changes with temperature, measurements must be taken at a fixed temperature.
Measuring range:
Conductivity: 1µS/cm to 100mS/cm | Temperature: 0 to 80 °C
|
Measurement parameters:
Conductivity | temperature
Manufacturer's number: 3014046709For general use Plastic housing, titanium/platinum black, k=1, conductivity cell with integrated temperature sensorWaterproofunder water measurements up to a depth of 1 meter
Measuring range:
pH: 0 to 14 | Temperature: 0 to 100°C
|
Measurement parameters:
pH | Temperature
Manufacturer number: 3200611623This glass-body, refillable pH electrode is recommended for a wide range of applications, including pH buffers and aqueous test solutions.Offers quick stability and drift reductionConstructed with responsive glass that is 10x stronger than JIS standardsThe dome-shaped tip provides strength in all directions, reducing damage concernsWaterproof, Pb-free glass
Measuring range:
pH: 0 to 14 | Temperature: 0 to 60°C
|
Measurement parameters:
pH | Temperature
Manufacturer number: 3200611627This glass-body, refillable pH electrode can measure samples as low as 50µL.Compatible with extremely small sample containers (e.g., microtubes)Temperature sensor is placed beside the bulb for quick responseWaterproof