Nitrate (NO3-) ion selective electrode for 300 seriesThe new electrode is suitable for the LAQUA WQ-300 series from Horiba and offers precise and reliable measurements for ions in aqueous solutions. It is characterised by its user-friendly handling and environmentally friendly design and can be used for a wide range of applications.Features:Measurement parameters: Nitrate (NO3-) Solid-state electrodes that do not require refillingDouble junction made of porous sintered polyethyleneIntegrated temperature sensor Environmentally friendly design made from bio-based plasticSupplied with calibration and ionic strength adjustment solutionsRobust housing made of polycarbonate and PVCLow maintenance, simply rinse and sealWaterproof according to IP67Linearity in measurement range:The range where the calibration curve has linearity is called the measurement range. When lower concentration is measured where the linearity is not established, perform calibration at two points in the lower concentration range.Influence of pH:The impact of the pH may cause a decrease in the slope of the ion selective electrode, or parallel shifting of the calibration curve. To prevent these effects, set the pH to an appropriate value in advance and keep it constant.Interfering ions:Ion selective electrodes have good selectivity with respect to the ions to be measured, but they may react to the other ions. When using the ion electrode method, it is important to know the effects of coexistent ions and take measures to avoid them. Interfering ions may form compounds with poor solubility or may form complex salts with the structure material of the ion selective membrane, these may to have a significant impact on the measured value.Conditioning:An electrode is conditioned by soaking it in a standard solution for 1 hour or longer. Use a standard solution whose concentration is 100 mg/L or more.In the following cases, perform conditioning of the electrode before calibration.• Before the first use.• Before use after storage for 2 weeks or longer.• If the electrode is less responsive.Calibration:Always calibrate with at least 2 calibration solutions which are 1 decade apart and bracket the expected measurement value.Use fresh calibration solutions and do not re-use them.• Below 10 ppm (mg/L)First solution between 1 and 10ppmSecond solution between 10 and 50 ppm• Between 10 and 100 ppm (mg/L)First solution between 10 and 100ppmSecond solution between 100 and 1000 ppm• Above 100 ppm (mg/L)First solution between 100 and 1000ppmSecond solution above 1000 ppmFurther information can be found in the data sheets in the download area of the store
Manufacturer's number: 3200697408
Ion-selective electrodes respond to the concentration of specific ions in the test fluid and are variable potential electrodes. They are used in combination with reference electrodes to measure the concentration of certain ions.
When measuring with an ion meter, the ion concentration can be read directly by calibrating with different standard solutions. Since the volume reading changes with temperature, the measurements must be taken at a fixed temperature.
The Horiba LAQUA 300 BNC adapter is an intermediate piece to connect an ion selective electrode to the Smart Sensor Module with cable to an 300 series meter. After prior clarification with our company, your previous pH and redox electrodes can, if applicable, be connected to the 300 series meter after a compatibility check.Manufacturer number: 3200821465
Cable with digital sensor head to accommodate the ion selective sensors.
Manufacturer Part Nr. :3200812203 (2 metres 300-I-2) 3200923560 (5 metres 300-I-5) Note: To use the ion selective sensors, the respective adapters are required.
Cable with digital sensor head to accommodate the ion selective sensors.
Manufacturer Part Nr. :3200812203 (2 metres 300-I-2) 3200923560 (5 metres 300-I-5) Note: To use the ion selective sensors, the respective adapters are required.
Horiba Y046 Sampling Sheet B
Contains 100 pcs. / boxuse for minute samples (minimum of 0.05 ml) and particulate-containing samples (e.g., soil extract) for the latter, please use sampling sheet holder and cover the sensor during measurement for LAQUAtwin and Twin pocket meters, except conductivity and salt EC modelsManufacturer Part Nr. 3200053858